 Method 515.1
The USEPA Method 515.1 is an analytical method that utilizes an ethyl ether extraction of finished drinking and ground water, concentrated to 5-mL (in methyl tert-butyl ether) after derivitization with diazomethane and a gas chromatograph equipped witha capillary column to perform the separation of the analytes. To detect the GC eluant, an electron capture (ECD) detector is used.
 