| Biotechnology Products for Biotechnology |
|
 |

2000 Geno/Grinder

- Unique vigorous up-and-down grinding/pulverizing action.
- Prepares plant material such as seeds, stems, roots, leaves, and certain animal tissue.
- Sample preparation is completed in about two minutes with the addition of 1-2 grinding balls to the sample along with a buffer solution.
- Handles two standard deep-well titer plates (5 in. long x 3 in. wide x 2 in. high).
- Supplied with height adjustment spacers to handle titer plates, racks, vials, and other configurations of up to 2 1/4 inches in height.
- A digital timer displays both the full timer setting along with the minutes and seconds remaining in the grinding cycle.
- An adjustable dial allows the operator to set the precise vertical grinding speed between 500 and 2000 strokes per minute.
- Two safety interlocks, a lockdown latch and a pneumatic cylinder stabilize the lid for safe operation.
- The clamping mechanism latches have secondary locking tabs for additional safety.
- Isolation of nucleic acids (DNA/RNA), proteins, enzymes and yeast.
- Automated mechanical disruption of plant and animal tissue.
- Cryogenic accessories available.
- Used in high-throughput laboratory screening facilities.
- Efficient micro-titer plate format.
- Elimination of cross-contamination.
|
| Specifications |
| Dimensions: | 20.5 in. (52 cm) widex 16.9 in. (43 cm) deep x 22 in. (56 cm) high |
| Weight: | 20.5 in. (52 cm) widex 16.9 in. (43 cm) deep x 22 in. (56 cm) high |
| Motor: | ½ HP |
| Power Cord: | 3-prong grounded plug for 115 V/60 Hz version |
| Fuse: | 10 Amp @ 115 V/60 Hz |
| Clamp Movement: | 1.25 in. (3.2 cm) vertical |
| Clamp Speed: | Adjustable from 500 to 1600 strokes/minute Speeds above 1200 not recommended for#2195 Large Capacity Clamp |
| Timer: | Digital in minutes: seconds, maximum 99:59(typical running times are under 2 minutes) |
| Specifications |
| Dimensions: | 20.5 in. (52 cm) widex 16.9 in. (43 cm) deep x 22 in. (56 cm) high |
| Weight: | 110 lbs. Net (50 kg), 168 lbs. Gross (76 kg) ½ HP |
| Motor: | ½ HP |
| Power Cord: | 2-prong European plug for 230 V/50 Hz version |
| Fuse: | 8 Amp @ 230 V/50 Hz |
| Clamp Movement: | 1.25 in. (3.2 cm) vertical |
| Clamp Speed: | Adjustable from 500 to 1600 strokes/minute Speeds above 1200 not recommended for#2195 Large Capacity Clamp |
| Timer: | Digital in minutes: seconds, maximum 99:59(typical running times are under 2 minutes) |
2600 Cryo-Station
A holding station for samples which must be kept chilled to preserve RNA for extraction. The insulated outer jacket of the Cryo-Station is chilled with liquid nitrogen and can be filled automatically or manually. Two titer plates can be placed in the Cryo-Station well to be filled and kept cold. The well can also hold a chilled cutting board to cut up sensitive samples for RNA analysis. |
2650 Cryo-Block
A single piece of extruded aluminum, to be chilled and then inserted into a 2210 Titer Plate. The Cryo-Block fingers fit the gaps between the round cells, and keep temperatures inside the cells low enough to preserve RNA. The Cryo-Block and Titer Plate combination can be used with or without the 2600 Cryo-Station. 2210 Titer Plate |
2195 Large Capacity Clamp Assembly
An oversize clamp that will hold centrifuge tubes or a double load of titer plates. Designed to hold twelve standard 50 ml centrifuge tubes (115 mm length) with 2196 Adapter, or twenty-four standard 15 ml centrifuge tubes (119 mm length) with 2197 Adapter. Also holds four deepwell titer plates, stacked two per side of clamp. Rubber mat for positioning between stacked titer plates is included. The 2195 Clamp Assembly is not available installed on the Geno/Grinder but must be purchased separately. Recommended for Geno/Grinder clamp speeds under 1200 strokes/minute. |
| See Also: 2196 Holder for 50 ml Centrifuge Tubes |
2200-100 (100/cs) 96-Well Titer Plate, Square Wells
96 Deep Well Plates are designed for multi-purpose applications such as sample libraries, mother-to-daughter automated plate pipetting, large sample dilutions and cell suspensions. Sold in cases of 100 plates.
2.4 ml volume wells with a 2.0 ml working volume. Alphanumeric designations for well identification. Manufactured of superior quality polypropylene. Designed for applications with single or multi-channel pipettors and automated liquid handling equipment. |
2201-10 (10/cs) Cap-Mats
Sealing mats for use with the 2200, 96-well titer plate listed above. Sold in cases of 10 mats. |
2210-100 96-Well Titer Plate, Round Wells, Case of 100
Round 2.0 ml wells, rugged polypropylene, alphanumeric marks for well identification. For use with the 2650 Cryo-Block, which is inserted in gaps between wells to keep plates and samples chilled to preserve RNA for extraction. |
6770 Freezer/Mill

- Cryogenic impact grinder with self contained liquid nitrogen tub and insulated case
- Hold one 6751 or 6771 sample vial for grinding, with the capacity to hold two additional vials in a pre cooling chamber
- Equipped with touch screen interface for flexibility and a removable control panel
- Capable of storing up to 10 grinding protocols
- Supplied with a 6754 Extractor/Vial Opener, 6755 Vial Rack, Controller Interconnect Cable (8 in/20.3cm), and power cord
- Grinds samples in the 0.1 gram to 5.0 gram range
|
| Specifications |
| Dimensions: | 19.5 in (49.5 cm) x 11 in (27.9 cm) x 13.3 in (33.6 cm) |
| Weight: | 18.0 lbs (8.2 kg) net; 22.0 lbs (9.9kg) gross |
| Voltage: | 115V/60Hz |
| Specifications |
| Dimensions: | 19.5 in (49.5 cm) x 11 in (27.9 cm) x 13.3 in (33.6 cm) |
| Weight: | 18.0 lbs (8.2 kg) net; 22.0 lbs (9.9kg) gross |
| Voltage: | 230V/50Hz |
6850 Freezer/Mill

- Larger cryogenic impact grinder with self-contained liquid nitrogen tub and insulated case.
- Holds one large capacity 6801 sample vial or four 6751 sample vials for grinding, with the capacity to hold one 6801 vial or four 6751 vials in a pre-cooling chamber.
- Equipped with speed control, programmable timer, and safety interlock.
- Supplied with Accessory Package that must be chosen to match choice of grinding containers, and a power cord (European CEE 7/7 twoprong power cord supplied with 6850-230 Freezer/Mill).
- Liquid nitrogen necessary for operation.
- Grinding containers and optional accessories sold separately.
- Grinds samples in the 1.0 gram to 100.0 gram range.
- 6820 Autofill option available.
|
| Specifications |
| Dimensions: | 23 in. (58 cm) x 21 in. (53 cm) x 23 in. (58 cm) |
| Weight: | 102 lbs. net (46 kg); 120 lbs. gross (55 kg) |
| Voltage: | 115 V/60 Hz |
| Specifications |
| Dimensions: | 23 in. (58 cm) x 21 in. (53 cm) x 23 in. (58 cm) |
| Weight: | 102 lbs. net (46 kg); 120 lbs. gross (55 kg) |
| Voltage: | 230 V/50 Hz |
6814 AutoExtractor
 The Model 6814 AutoExtractor is an electrically powered version of our catalog #6754/6804 manual extractors and vial openers. Cold vials can now be opened easily, making the grinding process more efficient. In medium to high-throughput laboratory facilities, operator fatigue associated with the manual extractors is eliminated, increasing the speed of sample processing. |

6900 Cryogenic Gloves
These cryogenic gloves are designed to protect the hands and arms from the hazards associated with ultra-cold materials. Highly recommended when operating the 6750 and 6850 Freezer/Mills. These multi-layer-insulated gloves are lightweight and flexible, allow excellent dexterity, and are comfortable to wear for extended periods of time. The gloves are sold as a pair and are available in small (6900S), medium (6900M), large (6900L) and X-large (6900XL). |
 |
| Grinding Containers and Accessories for the 6770 SPEX SamplePrep Freezer/Mill |

6751 Grinding Vial Set
Set includes stainless steel impactor and two end plugs, plus four polycarbonate center cylinders (6751C4).Transparent plastic allows visual check of grinding progress. Sample capacity 0.5 ml to 4.0 ml. |
6751C4 Polycarbonate Center Cylinder
For 6751 vial set; sold in units of 4. Also sold in units of 20 (6751C20). Polycarbonate is durable and transparent but should not be cleaned with organic solvents. |

6752 Steel Center Cylinder
For 6751 vial set. Replaces 6751C when sample contact with plastic is not advised. Made of nonmagnetic stainless steel. |

6753 Microvial Set
Three 6753V Microvials with holder. Each 6753V has stainless steel end plugs, center cylinder and impactor. Holder contains three 6753V Microvials for simultaneous operation. Sample capacity 0.1 - 0.5 ml each. |

6754 Extractor/Vial Opener
The Extractor/Vial Opener lifts vial sets in and out of the Freezer/Mill, and is used to remove the vial end plugs from the center section. One 6754 is supplied with each 6750 Freezer/Mill and the 6800B and 6800C Accessory Packages. |

6755 Vial Rack
For 6751 vial set. Glass-reinforced acetal rack holds up to sixteen 6751 vial sets for storage and handling. One supplied with each 6750 Freezer/Mill, and 6850 Freezer/Mill Accessory Packages described on the Grinding Containers and Accessories page. |
 |
| Grinding Containers and Accessories for the 6850 SPEX SamplePrep Freezer/Mill |
6820 Auto-Fill System for the 6850 Freezer/Mill®
The 6820 Auto-Fill System is designated to automatically maintain the required level of liquid nitrogen within the 6850 Freezer/Mill during operation. The Auto-Fill System is a more efficient and safer way to handle the volume of liquid nitrogen required for processing samples in the 6850 Freezer/Mill. This automated system reduces the loss of liquid nitrogen and saves the time lost when manually filling the reservoir.
The Auto-Fill System requires a cryogenic transfer hose, not included with the 6820 package. These transfer hoses are available in different lengths and can be constructed with different materials. The transfer hose must be configured with a 1/2 inch JIC female flare nut at each end for proper installation. The 6820 system is supplied with a safety relief valve that connects to the liquid nitrogen supply via a 1/2 inch JIC female flare nut.
The Auto-Fill System is available as an option that can be installed when you place an order for a 6850 Freezer/Mill or as a retrofit package for 6850 systems that are already in service.
Please contact SPEX SamplePrep for further details. |

6801 Grinding Vial Set
Set includes stainless steel impactor and two end plugs, plus four polycarbonate center cylinders (6801C4). Transparent plastic allows visual check of grinding progress. Sample capacity up to 50 ml. |
6801C4 Polycarbonate Center Cylinder
For 6801 vial set; sold in units of 4. Also sold in units of 20 (6801C20). Polycarbonate is durable and transparent but should not be cleaned with organic solvents. |

6804 Extractor/Vial Opener
The Extractor/Vial Opener lifts vial sets in and out of the Freezer/Mill, and is used to remove the vial end plugs from the center section. One 6804 is supplied with the 6800A and 6800C Accessory Packages. |
6805 Vial Rack
For 6801 vial set. Epoxy-coated, steel wire rack holds up to six 6801 vial sets for storage and handling. One supplied with the 6800A and 6800C Accessory Packages. |
6806 Multi-Vial Adapter
Required when using four 6751 vial sets in a 6850 Freezer/Mill. The multi-vial adapter is an insert that is placed in the vial chamber of the coil to seperate four 6751 vial sets during the grinding. One supplied with the 6800B and 6800C accessory Packages. |

6800A Accessory Package
Order when operating 6850 Freezer/Mill with 6801 vial sets. Includes one 6804 Extractor/Vial Opener and one 6805 Vial Rack. |

6800B Accessory Package
Order when operating with multiple 6751 vial sets in the 6850 Freezer/Mill. Includes one 6754 Extractor/Vial Opener along with one 6755 Vial Rack and one 6806 Multi-Vial Adapter. |

6800C Accessory Package
Optional package at an additional cost. Order when operating with both 6751 and 6801 vial sets in a 6850 Freezer/Mill. Includes complete 6800A and 6800B Accessory Packages. |
|
|